ICU Medical, Inc.
HomeICU Medical ProductsAbout ICU MedicalInvestors World Leader in Safety Medical Systems
MicroCLAVE® Connector

 

 

 

 

 

 

 

Product Information
MicroCLAVE Video
MicroCLAVE Neutral Displacement Video
Technical Specifications
Product Literature
White Papers
Published Studies & Clinical Reports
Downloadable Videos
Frequently Asked Questions

 

 

 

Introducing the MicroCLAVE® Neutral Displacement Connector
 

 

Product Information

MicroCLAVE is a neutral displacement connector. This means that there is virtually no reflux of blood into the catheter lumen either when you connect or disconnect an administration device. Neutral displacement allows the healthcare provider to use one standard protocol throughout the hospital for clamping central and peripheral catheters. There is virtually no learning curve or special design needs of the MicroCLAVE which allow it to integrate easily into a healthcare system no matter how large.

MicroCLAVE utilizes the existing silicone seal technology which provides the superior sealing mechanism important to protect the IV system from microbiological contamination. Although the current CLAVE had the lowest deadspace of any needlefree connector at 0.06cc, this feature was improved upon in the MicroCLAVE to a 0.04cc as precise fluid delivery volumes are paramount in children. However, the most significant improvement to the MicroCLAVE for Pediatrics is the new streamlined design while still providing the popular recess for secure gripping with the fingers. The overall weight is 0.85g less or 32%! The width is 0.1" smaller and the height is marginally taller to accommodate the special designed clear luer lock.

To see how the MicroCLAVE Connector works please watch our video.

 

Technical Specifications

Flowrate:
Deadspace:
Backpressure:
Width:
Height:
Weight:
Other Features:

165mL / min.
0.04mL
75psig+
600
11.0mm
32.3mm
Latex Free
 

 

Product Literature
MicroCLAVE Literature: MicroCLAVE White Papers:
MicroCLAVE Product Brochure MicroCLAVE compared to the original CLAVE Connector
MicroCLAVE DFU Literature  

 

 
Published Papers & Clinical Reports for the MicroCLAVE:
Bouza, E. A Needleless Closed System Device
Maragakis, L MD, Bradley, K. RN, BSN. Increased Catheter-Related Bloodstream Infection Rates After the Introduction of a New Mechanical Valve Intravenous Access Port
Ryder PhD MS RN, Bacterial Transfer Through NeedleFree Connectors Poster
Bharti Asnani, M.D., Elian Abrutyn, M.D. Increased Catheter-Associated Bloodstream Infection Rates After the Introduction of a New Positive Pressure Mechanical Valve Intravenous Access Device
Get the Free Adobe® PDF Reader® to View Our Product Literature:

et Adobe Reader

 

Downloadable Product Videos
The following high quality videos are in the Windows Media® format:
MicroCLAVE High Resolution Video (640x480, 8MB)
MicroCLAVE Low Resolution Video (320x240, 2MB)
MicroCLAVE Neutral Displacement High Resolution Video (320x240, 20MB)
MicroCLAVE Neutral Displacement Low Resolution Video (320x240, 5MB)